Published 2001
| Version v1
Miscellaneous
Open
Influence of the secondary circuit chemistry on the characteristics of the filmed carbon steel components
- 1. Institute for Nuclear Research, Pitesti (Romania)
Description
Some correlations are established between the characteristics of the superficial films formed on the carbon steel components in some operation conditions of a secondary circuit from Nuclear Power Station (NPS), and the specific parameters of the aqueous environment in which these films were formed. The main parameters studied, specific to a secondary circuit environment, are: the value of pH and the substances used to regulate it and, respectively, the oxygen concentration dissolved in the aqueous environment. These filmed samples by autoclaving were studied by: X rays diffraction method; metallographic microscopy and electrochemical methods such as: potentiodynamic and electrochemical impedance spectroscopy (E.I.S.). (R.P.)
Files
33018430.pdf
Files
(254.3 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:adc21f9cf3df13e9bd22be24df1a2bcb
|
254.3 kB | Preview Download |
Additional details
Publishing Information
- Publisher
- Paks Nuclear Power Plant Co. Ltd.
- Imprint Title
- 5. International seminar on primary and secondary side water chemistry of nuclear power plants
- Imprint Pagination
- 235 p.
- Journal Page Range
- p. 131-137
- Report number
- INIS-HU--005
Conference
- Title
- 5. International seminar on primary and secondary side water chemistry of nuclear power plants
- Dates
- 17-20 Sep 2001
- Place
- Eger (Hungary)
INIS
- Country of Publication
- Hungary
- Country of Input or Organization
- Hungary
- INIS RN
- 33018430
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- FILMS; NUCLEAR POWER PLANTS; PH VALUE; REACTOR COMPONENTS; SECONDARY COOLANT CIRCUITS; WATER CHEMISTRY
- Descriptors DEC
- CHEMISTRY; COOLING SYSTEMS; ENERGY SYSTEMS; NUCLEAR FACILITIES; POWER PLANTS; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; THERMAL POWER PLANTS
Optional Information
- Notes
- 7 refs.