A protocol for the commissioning and quality assurance of new planning computers

Description

Any new radiotherapy planning system needs to be thoroughly tested. Besides checking the accuracy of the algorithm by comparing plans done on the system with measurements done in a phantom, it is desirable for the user to compare the new equipment with a tried and tested system before it is used clinically. To test our recently purchased planning systems, a protocol was developed for running a comparison between these and our existing planning computer, an IGE RTPLAN. A summary of the test protocol that was developed is as follows: (1) A series of plans is created on the old system, to include at least one plan of each common type. The series includes at least one plan with a bone inhomogeneity, and one with an air or lung inhomogeneity, and these plans are computed both with and without inhomogeneity correction. Point dose calculations are made for a number of positions on each plan, including the dose at the centre of the treatment volume. (2) Each of these plans is reproduced as accurately as possible on the new system using the original CT data and patient outlines. (3) The old and new plans, including those with and without inhomogeneity correction are overlaid and compared using the following criteria: (a) how well the volumes of interest coincide, (b) how accurately the positions of the points of interest are reproduced, (c) the doses at the points of interest, (d) the distances between the isodoses defining the dose plateau, (e) the maximum displacement between the corresponding pairs of isodoses in the dose gradient around the tumour. The protocol has been used to test two systems: the (newly developed) Siemens Axiom and the Helax TMS (running on a DEC Alpha). A summary of the results obtained will be presented. These were sufficient to show up several minor problems, particularly in the Axiom system

Additional details

Identifiers

PII
0167814096805299;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
37
Journal Issue
3
Journal Page Range
p. S26
ISSN
0167-8140
CODEN
RAONDT

INIS

Country of Publication
Ireland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
34044625
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCURACY; EQUIPMENT; IRRADIATION DEVICES; ISODOSE CURVES; PERFORMANCE TESTING; QUALITY ASSURANCE; RADIOTHERAPY
Descriptors DEC
MEDICINE; NUCLEAR MEDICINE; RADIOLOGY; TESTING; THERAPY

Optional Information

Copyright
Copyright (c) 1995 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.