Published March 1989
| Version v1
Report
Restricted
An analysis of MB-2 100% steam line break test T-2013 using RELAP5/MOD2
Description
This report presents RELAP5/MOD2 calculations of the 100% steam line break test T-2013 performed on the Westinghouse Model Boiler-2 facility (MB-2). The input deck uses a noding structure typical of what would be used for an integral rig or full plant study using the RELAP5/MOD2 code. Sensitivity calculations were performed for the break junction discharge coefficient and the separator drain line loss coefficient. (author)
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Publishing Information
- Imprint Pagination
- 27 p.
- Report number
- AEEW-R--2477
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 21040486
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- FLOW MODELS; R CODES; RUPTURES; STEAM LINES
- Descriptors DEC
- COMPUTER CODES; FAILURES; MATHEMATICAL MODELS; PIPELINES