Published March 1989 | Version v1
Report Restricted

An analysis of MB-2 100% steam line break test T-2013 using RELAP5/MOD2

Description

This report presents RELAP5/MOD2 calculations of the 100% steam line break test T-2013 performed on the Westinghouse Model Boiler-2 facility (MB-2). The input deck uses a noding structure typical of what would be used for an integral rig or full plant study using the RELAP5/MOD2 code. Sensitivity calculations were performed for the break junction discharge coefficient and the separator drain line loss coefficient. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
27 p.
Report number
AEEW-R--2477

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
21040486
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Descriptors DEI
FLOW MODELS; R CODES; RUPTURES; STEAM LINES
Descriptors DEC
COMPUTER CODES; FAILURES; MATHEMATICAL MODELS; PIPELINES