Published November 2019 | Version v1
Journal article

Optimal allocation of heat exchangers in a Supercritical carbon dioxide power cycle for waste heat recovery

  • 1. Department of Mechanical and Aerospace Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826 (Korea, Republic of)
  • 2. Thermal Energy Systems Laboratory, Korea Institute of Energy Research, 152 Gajeong-ro, Yuseong-gu, Daejeon 34129 (Korea, Republic of)
  • 3. School of Energy Systems Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974 (Korea, Republic of)

Description

Highlights: • The net power of the sCO2 cycle for waste heat recovery increases with a preheater. • The optimal allocation of heat exchangers is existed to generate maximum net power. • The CO2 split ratio has an optimal point to maximize the net power. • The CO2 split ratio and turbine inlet temperature are linear at the maximum power. -- Abstract: Supercritical carbon dioxide (sCO2) power cycles have attracted attention because of their high efficiency and flexibility in various temperature heat sources including low-temperature waste heat applications. In waste heat applications, the size of the heat exchangers is an important issue because of the trade-off between performance and installation cost. For the optimal design of an sCO2 cycle for waste heat recovery, a thermodynamic model for the basic cycle and the preheating cycle was constructed. The heat exchangers were then modeled by a finite volume analysis under the fixed total UA value, with the equivalent conductance representing the size of the heat exchanger. The net power and thermal efficiency of the cycle were calculated. The results of the optimization confirmed that the application of the preheater improves the performance of the basic cycle, and an optimum point of the split ratio exists. From the simulation, with an increase in the turbine inlet temperature (TIT), the thermal efficiency improves, but the net power does not always increase. Instead, a close linearity between the optimum CO2 split ratio (ϕ) and the turbine inlet temperature was found at the maximum net power, even under different turbine inlet pressures and total UA values. From these results, the configuration of heat exchangers for waste heat applications can be planned appropriately to operate at the maximum net power.

Additional details

Identifiers

DOI
10.1016/j.enconman.2019.112002;
PII
S0196890419310088;

Publishing Information

Journal Title
Energy Conversion and Management
Journal Volume
199
Journal Page Range
vp.
ISSN
0196-8904
CODEN
ECMADL

Optional Information

Copyright
Copyright (c) 2019 Elsevier Ltd. All rights reserved.