Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience

  • 1. University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland)
  • 2. University Hospital Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland)
  • 3. Massachusetts General Hospital and Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States)

Description

The objective was to prospectively investigate the diagnostic accuracy of high-pitch (HP) dual-source computed tomography coronary angiography (CTCA) compared with catheter coronary angiography (CCA) for the diagnosis of significant coronary stenoses. Thirty-five patients (seven women; mean age 62 ± 8 years) underwent both CTCA and CCA. CTCA was performed with a second-generation dual-source CT system permitting data acquisition at an HP of 3.4. Patients with heart rates >60 bpm were excluded from study enrolment. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a four-point scale (1: excellent to 4: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). CCA served as the standard of reference. Radiation dose values were calculated using the dose-length product. Diagnostic image quality was found in 99% of all segments (455/459). Non-diagnostic image quality occurred in a single patient with a sudden increase in heart rate immediately before and during CTCA. Taking segments with non-evaluative image quality as positive for disease, the sensitivity, specificity and positive and negative predictive values were 94, 96, 80 and 99% per segment and 100, 91, 88 and 100% per patient. The effective radiation dose was on average 0.9 ± 0.1 mSv. In patients with heart rates ≤60 bpm, CTCA using the HP mode of the dual-source CT system is associated with high diagnostic accuracy for the assessment of coronary artery stenoses at sub-milliSievert doses. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00330-009-1618-9

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology
Journal Volume
19
Journal Issue
12
Journal Page Range
p. 2896-2903
ISSN
0938-7994
CODEN
EURAE3

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
41000089
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCURACY; COMPUTERIZED TOMOGRAPHY; CORONARIES; VASCULAR DISEASES
Descriptors DEC
ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; ORGANS; TOMOGRAPHY