TU-F-18A-06: Dual Energy CT Using One Full Scan and a Second Scan with Very Few Projections
Description
Purpose: The conventional dual energy CT (DECT) requires two full CT scans at different energy levels, resulting in dose increase as well as imaging errors from patient motion between the two scans. To shorten the scan time of DECT and thus overcome these drawbacks, we propose a new DECT algorithm using one full scan and a second scan with very few projections by preserving structural information. Methods: We first reconstruct a CT image on the full scan using a standard filtered-backprojection (FBP) algorithm. We then use a compressed sensing (CS) based iterative algorithm on the second scan for reconstruction from very few projections. The edges extracted from the first scan are used as weights in the Objectives: function of the CS-based reconstruction to substantially improve the image quality of CT reconstruction. The basis material images are then obtained by an iterative image-domain decomposition method and an electron density map is finally calculated. The proposed method is evaluated on phantoms. Results: On the Catphan 600 phantom, the CT reconstruction mean error using the proposed method on 20 and 5 projections are 4.76% and 5.02%, respectively. Compared with conventional iterative reconstruction, the proposed edge weighting preserves object structures and achieves a better spatial resolution. With basis materials of Iodine and Teflon, our method on 20 projections obtains similar quality of decomposed material images compared with FBP on a full scan and the mean error of electron density in the selected regions of interest is 0.29%. Conclusion: We propose an effective method for reducing projections and therefore scan time in DECT. We show that a full scan plus a 20-projection scan are sufficient to provide DECT images and electron density with similar quality compared with two full scans. Our future work includes more phantom studies to validate the performance of our method
Additional details
Identifiers
- DOI
- 10.1118/1.4889342;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 41
- Journal Issue
- 6
- Journal Page Range
- p. 476
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46113695
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S60: APPLIED LIFE SCIENCES;
- Descriptors DEI
- ALGORITHMS; CAT SCANNING; ELECTRON DENSITY; IMAGE PROCESSING; ITERATIVE METHODS; MOTION; PATIENTS; PHANTOMS; SPATIAL RESOLUTION; TEFLON
- Descriptors DEC
- CALCULATION METHODS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; FLUORINATED ALIPHATIC HYDROCARBONS; HALOGENATED ALIPHATIC HYDROCARBONS; MATERIALS; MATHEMATICAL LOGIC; MOCKUP; ORGANIC COMPOUNDS; ORGANIC FLUORINE COMPOUNDS; ORGANIC HALOGEN COMPOUNDS; ORGANIC POLYMERS; PETROCHEMICALS; PETROLEUM PRODUCTS; PLASTICS; POLYETHYLENES; POLYMERS; POLYOLEFINS; POLYTETRAFLUOROETHYLENE; PROCESSING; RESOLUTION; STRUCTURAL MODELS; SYNTHETIC MATERIALS; TOMOGRAPHY
Optional Information
- Notes
- (c) 2014 American Association of Physicists in Medicine