Differing responses in right and left ventricular filling, loading and volumes during positive end-expiratory pressure
- 1. Yale Univ. School of Medicine, New Haven, CT (USA)
Description
Using a combined hemodynamic and radionuclide technique, 20 patients with varied ventricular function were evaluated during positive end-expiratory pressure (PEEP) application. Left ventricular (LV) and right ventricular (RV) ejection fractions and cardiac output were measured, and ventricular volumes were derived. Seven patients (group 1) who had an increase in LV end-diastolic volume with PEEP and 13 patients (group 2) who had the more typical response, a decrease in LV end-diastolic volume with PEEP, were identified. Compared with group 2, group 1 patients had a higher incidence of coronary artery disease (5 of 7 vs 1 of 13, p less than 0.005) and lower cardiac output (3.9 +/- 1.6 vs 9.1 +/- 3.2 liters/min, p less than 0.005), LV ejection fraction (27 +/- 13 vs 51 +/- 21%, p less than 0.05), RV ejection fraction (15 +/- 6 vs 32 +/- 8%, p less than 0.005) and peak filling rate (1.32 +/- 0.43 vs 3.51 +/- 1.70 end-diastolic volumes/s, p less than 0.05). LV and RV volumes increased and peak filling rate decreased with PEEP in group 1, whereas in group 2 LV volume decreased and RV volume and peak filling rate remained unchanged. Using stepwise regression analysis, the change in LV volume with PEEP was related directly to baseline systemic vascular resistance and inversely to baseline blood pressure. Similarly, the change in peak filling rate with PEEP was inversely related to the change in RV end-diastolic volume. Thus, the hemodynamic response to PEEP is heterogeneous and may be related to LV ischemia
Additional details
Publishing Information
- Journal Title
- American Journal of Cardiology
- Journal Volume
- 64
- Journal Issue
- 12
- Series
- Am. J. Cardiol.
- Journal Page Range
- 772-777
- ISSN
- 0002-9149
- CODEN
- AJCDA
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 21028115
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BLOOD PRESSURE; CARDIOVASCULAR DISEASES; DIAGNOSIS; ERYTHROCYTES; HEART; IMAGE PROCESSING; PATIENTS; TECHNETIUM ISOTOPES; TRACER TECHNIQUES
- Descriptors DEC
- BIOLOGICAL MATERIALS; BLOOD; BLOOD CELLS; BODY; BODY FLUIDS; CARDIOVASCULAR SYSTEM; DISEASES; ISOTOPE APPLICATIONS; MATERIALS; ORGANS