Published July 2005 | Version v1
Journal article

Study of the personal radiation dose received by nuclear medicine technologists working in a dedicated PET centre

  • 1. Austin Health, Victoria (Australia)
  • 2. Australian Radiation Services, Victoria (Australia)

Description

The use of dedicated PET scanners is becoming more widespread throughout Australia and the world. PET imaging utilises short-lived (-108 min), high-energy (511 keV) gamma-ray emitters, that could result in a high radiation dose being received by staff. As part of a larger staff and area monitoring project, this paper discusses the personal dose equivalent, Hp (10), received by PET staff working in a dedicated PET centre. The typical H (10) received by staff was approximately 31 μSv. The average daily administered activity to patients at Austin Health was 1280 MBq

Additional details

Publishing Information

Journal Title
Radiation Protection in Australasia
Journal Volume
22
Journal Issue
2
Journal Page Range
p. 40-45
ISSN
1444-2752

Optional Information

Notes
5 refs., 4 tabs.