The High Voltage distribution system of the ATLAS Tile Calorimeter and its performance during data taking

  • 1. Laboratoire de Physique de Clermont-Ferrand, Université Clermont Auvergne, CNRS/IN2P3, 4 avenue Blaise Pascal, Aubière (France)
  • 2. Laboratório de Instrumentação e Física Experimental de Partículas, LIP, Av. Gama Pinto, n. 2, Lisboa (Portugal)

Description

This article documents the characteristics of the high voltage (HV) system of the hadronic calorimeter TileCal of the ATLAS experiment. Such a system is suitable to supply reliable power distribution into particles physics detectors using a large number of PhotoMultiplier Tubes (PMTs). Measurements performed during the 2015 and 2016 data taking periods of the ATLAS detector show that its performance, in terms of stability and noise, fits the specifications. In particular, almost all the PMTs show a voltage instability smaller than 0.5 V corresponding to a gain stability better than 0.5%. A small amount of channels was found not working correctly. To diagnose the origin of such defects, the results of the HV measurements were compared to those obtained using a Laser system. The analysis shows that less than 0.2% of the about 10 thousand HV channels were malfunctioning.

Availability note (English)

Available from http://dx.doi.org/10.1088/1748-0221/13/08/P08006

Additional details

Publishing Information

Journal Title
Journal of Instrumentation
Journal Volume
13
Journal Issue
08
Journal Page Range
p. P08006
ISSN
1748-0221

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
51051049
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
ATLAS DETECTOR; CALORIMETERS; COMPARATIVE EVALUATIONS; DEFECTS; DIAGNOSIS; DISTRIBUTION; NOISE; PERFORMANCE; PHOTOMULTIPLIERS; STABILITY; TUBES
Descriptors DEC
EVALUATION; MEASURING INSTRUMENTS; PHOTOTUBES; RADIATION DETECTORS