Published 2005 | Version v1
Journal article

Advanced motion correction methods in PET

Creators

  • 1. Johns Hopkins University, School of Medicine, Department of Radiology, Baltimore (United States)

Description

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of motion (most often studies in PET brain imaging), conventional motion-correction algorithms have relied on extraction of the motion information from the emission data itself: However, the accuracy of motion compensation in this approach is degraded by the noisy nature of the emission data. Subsequently. advanced methods, as reviewed in this work, make use of external real-time measurements of motion. Various image-based and projection-based correction methods have been discussed and compared. The paper also reviews recent and novel applications that perform corrections for cardiac and respiratory motions. Unlike conventional gating schemes, in which the cardiac and respiratory gated frames are independently reconstructed (resulting in noisy images), the reviewed methods are seen to follow a common trend of seeking to produce images of higher quality by making collective use of all the gated frames (and the estimated motion). As an observation, a general theme in motion-correction methods is seen to be the use of increasingly sophisticated software to make use of existing advanced hardware. In this sense, this field is very open to future novel ideas hardware, and especially software) aimed at improving motion detection, characterization and compensation

Availability note (English)

Available from Atomic Energy Organization of Iran

Additional details

Publishing Information

Journal Title
Iranian Journal of Nuclear Medicine
Journal Volume
13
Journal Issue
no.24
Journal Page Range
p. 1-17
ISSN
1681-2824

INIS

Country of Publication
Iran, Islamic Republic of
Country of Input or Organization
Iran, Islamic Republic of
INIS RN
37016455
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CARDIOVASCULAR SYSTEM; EMISSION; NUCLEAR MEDICINE; PATIENTS; POSITRON COMPUTED TOMOGRAPHY; RESPIRATORY SYSTEM; SPATIAL RESOLUTION
Descriptors DEC
COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; MEDICINE; RESOLUTION; TOMOGRAPHY