Published 1990 | Version v1
Book

Lymphoscintigraphy of the lower extremity

Creators

  • 1. Centre for Nuclear Studies, Pakistan Atomic Energy Commission Islamabad (Pakistan)

Description

Fifty one lower extremities of 26 normal healthy volunteers and 26 extremities of 13 patients with oedema have been studied. Dynamic quantitative lymphoscintigraphy using 99Tc-m antimony sulphide colloid during passive exercise as well as before and after active exercise was performed. parameters of lymphatic function including percentage of radioactivity cleared from the injection site, the percentage uptake by the inguinal lymph nodes, the time of arrival of activity at the regional lymph nodes and the lymphatic reserve index have been evaluated. The percentage clearance of activity from the injection site was found technically difficult to standardize and proved to be an unreliable parameter of lymphatic function. However, the quantitation of nodal uptake, the lymphatic transit time and the lymphatic reserve capacity accurately depicted the lymphatic functional status of an individual. The physiologic parameters of lymphatic function of the contralateral lower extremities were compared and a physiologic difference in the lymphatic capacity of the two limbs was scintigraphically documented. (author)

Additional details

Publishing Information

Publisher
Centre for Nuclear Studies.
Imprint Place
Islamabad (Pakistan)
Imprint Title
Current trends in nuclear medicine in Pakistan
Imprint Pagination
540 p.
Journal Page Range
p. 209-238.