Gamma-ray isotopic measurements for assay of plutonium fuels

Description

The data presented summarize experience in obtaining plutonium and americium isotopic data using two systems: a 70 cc Ge(Li) system with 1.8 keV resolution at 1332 keV for acquisition of spectra up to 700 keV gamma-ray energy and a 1 cc planar system with 600 eV resolution at 122 keV for the acquisition of spectra up to 220 keV. Plutonium samples include ash samples with plutonium-240 concentrations of 9 to 20 percent; plutonium metal samples 6 percent--plutonium-240; ZPPR fuel pins; and various waste categories of 6 percent--plutonium-240 material. Nondestructive isotopic ratios obtained by gamma-ray spectroscopy are compared to chemical data obtained from these samples

Availability note (English)

MF available from INIS under the Report Number.

Files

8284452.pdf

Files (823.5 kB)

Name Size Download all
md5:efa925f8de4090f7e8974e2718b1b911
823.5 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
13 p.
Report number
MLM--2336(OP)

Conference

Title
17. annual meeting of the institute of nuclear materials management.
Dates
23 Jun 1976.
Place
Seattle, Washington, United States of America (USA).

Optional Information

Notes
Available from NTIS. $3.50.