Published February 1989 | Version v1
Journal article

Primary ionization cluster counting with low-pressure multistep detectors

  • 1. Weizmann Institute of Science, Rehovot (Israel)

Description

The authors describe a new method of Primary ionization Cluster Counting (PCC), using a low-pressure multistep counter coupled to a conversion volume. Due to the small density of the primary clusters in the low-pressure gas, and to the high gain of the multistep amplification structure, the clusters are efficiently counted. Taking advantage of the enhanced relativistic rise at low gas pressures, and the reduced interference from δ-electrons, the PCC can be efficiently applied to dE/dx relativistic charged particle identification. The authors present here preliminary results obtained with relativistic electrons and a UV laser. For minimum ionizing electrons we counted about 2 primary clusters/cm, at 20 Torr of isobutane. The distribution is poissonian. The PCC is shown to be an efficient tool for the study of the primary ionization process in gas media

Additional details

Publishing Information

Journal Title
IEEE Transactions on Nuclear Science
Journal Volume
36
Journal Issue
1
Series
IEEE Trans. Nucl. Sci.
Journal Page Range
316-323
ISSN
0018-9499
CODEN
IETNA

Conference

Title
IEEE nuclear science symposium.
Dates
9-11 Nov 1988.
Place
Orlando, FL (USA).

Optional Information

Secondary number(s)
CONF-881103--.