Calibration services for radiodiagnostic X ray beam quality based on IAEA TRS457 guidance are being prepared by Secondary Standard Dosimetry Laboratory Jakarta, Indonesia. The RQR beam quality measurement has been completed, and most radiodiagnostic facility using general X ray equipment is our priority. Study of the characteristics of X ray spectra using XCOMP5R and Monte Carlo have also been undertaken for selected energy of the SSDL's X ray machine to evaluate the effective energy of Xray spectra. The measurements are done using Farmer type chamber NE2571 and Keithley Electrometer. The HVL measurements were undertaken based on IAEA TRS457 configuration; the additional filters are located 50cm from the source while detector is positioned at 100cm. All spectra of RQR beam quality were evaluated by using XCOMP5R. The RQR2, RQR5 and RQR10 spectra were evaluated using BEAMnrc monte carlo code. The X ray spectrum, effective energy and FWHM from XCOMP5R are compared with BEAMnrc. FWHM of each spectrum was calculated using correlation between standard deviation (δ) and FWHM with Gaussian distribution as the basis of calculation. The following equation is used FWHM= 2√2In(2) δ. Peaks of Spectrum of X ray characteristic appear for tube voltage above 70kV. In order to have Gaussian distribution the peak need to be removed since it will affect the relationship between standard deviation and FWHM
Additional details
Publishing Information
- Imprint Title
- International Symposium on Standards, Applications and Quality Assurance in Medical Radiation Dosimetry (IDOS). Book of Extended Synopses
- Imprint Pagination
- 670 p.
- Journal Page Range
- p. 197-198
- Report number
- IAEA-CN--182
Conference
- Title
- International Symposium on Standards, Applications and Quality Assurance in Medical Radiation Dosimetry (IDOS)
- Dates
- 9-12 Nov 2010
- Place
- Vienna (Austria)
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42046176
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S62: RADIOLOGY AND NUCLEAR MEDICINE; S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BEAMS; CALIBRATION; ELECTROMETERS; EVALUATION; GAUSS FUNCTION; INDONESIA; MONTE CARLO METHOD; SSDL; X-RAY EQUIPMENT; X-RAY SPECTRA
- Descriptors DEC
- ASIA; CALCULATION METHODS; DEVELOPING COUNTRIES; ELECTRIC MEASURING INSTRUMENTS; ELECTRICAL EQUIPMENT; EQUIPMENT; FUNCTIONS; ISLANDS; MEASURING INSTRUMENTS; SPECTRA
Optional Information
- Notes
- 5 refs, 1 fig, 1 tab
- Secondary number(s)
- IAEA-CN--182-050