Small metal soft tissue foreign body extraction by using 3D CT guidance: A reliable method
Creators
- 1. Department of Plastic Surgery, General Hospital of Shenyang Military Command, PLA, Shenyang 110016 (China)
- 2. Department of Radiology, General Hospital of Shenyang Military Command, 83 Wenhua Steet, Shenhe District, Shenyang 110016, Liaoning Province (China)
Description
Objective: To introduce a useful and accurate technique for the locating and removal of small metal foreign bodies in the soft tissues. Methods: Eight patients presented with suspected small metal foreign bodies retained in the soft tissues of various body districts. Under local anesthesia, 3–6 pieces of 5 ml syringe needles or 1 ml syringe needles were induced through three different planes around the entry point of the foreign bodies. Using these finders, the small metal FBs were confirmed under 3D CT guidance. Based on the CT findings, the soft tissues were dissected along the path of the closest needle and the FBs were easily found and removed according to the relation with the closest needle finder. Results: Eight metal foreign bodies (3 slices, 3 nails, 1 fish hook, 1 needlepoint) were successfully removed under 3D CT guidance in all patients. The procedures took between 35 min and 50 min and the operation times took between 15 min and 25 min. No complications arose after the treatment. Conclusion: 3D CT-guided technique is a good alternative for the removal of small metal foreign body retained in the soft tissues as it is relatively accurate, reliable, quick, carries a low risk of complications and can be a first-choice procedure for the extraction of small metal foreign body.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2012.01.002Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2012.01.002;
- PII
- S0720-048X(12)00003-4;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 81
- Journal Issue
- 11
- Journal Page Range
- p. 3339-3343
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 45027672
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ANESTHESIA; ANIMAL TISSUES; COMPUTERIZED TOMOGRAPHY; HAZARDS; METALS; NAILS; PATIENTS; REMOVAL; SURGERY; THREE-DIMENSIONAL CALCULATIONS
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; ELEMENTS; MEDICINE; ORGANS; SKIN; TOMOGRAPHY