Published May 2001 | Version v1
Miscellaneous

Seismic response time history analyses for KALIMER building with a horizontal and vertical seismic isolation

  • 1. KAERI, Taejon (Korea, Republic of)

Description

The seismic response time history analyses for the lumped mass models of KALIMER reactor building with a horizontal and vertical seismic isolation are performed for Artificial Time History and Kobe earthquake. The vertical amplification by the horizontal isolation is reduced by a vertical isolation for both earthquakes. The 3% viscous damping and the vertical isolation frequency of 1.5Hz gives a reduced vertical response compared to the fixed base condition at reactor support, and the 9% viscous damping to Kobe earthquake is required to get an equivalent vertical response with a fixed base condition

Part of:
Proceedings of the Korean Nuclear Society spring meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the Korean Nuclear Society spring meeting
Imprint Pagination
[ONE CDROM]
Journal Page Range
[9 p.]

Conference

Title
2001 spring meeting of the Korean Nuclear Society
Dates
24-25 May 2001
Place
Cheju (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
33040741
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
BUILDINGS; DAMPING; EARTHQUAKES; LIQUID METAL COOLED REACTORS; RISK ASSESSMENT; SEISMIC EFFECTS; SEISMIC ISOLATION; VISCOUS FLOW
Descriptors DEC
FLUID FLOW; REACTORS; SEISMIC EVENTS

Optional Information

Notes
4 refs, 6 figs, 5 tabs