Published May 2001 | Version v1
Miscellaneous

Leakage test of Ir-192 sealed radiation sources for non-destructive testing

  • 1. KAERI, Taejon (Korea, Republic of)
  • 2. KINS, Taejon (Korea, Republic of)

Description

Leakage tests were performed to verify the leak tightness of Ir-192 sealed radiation source for industrial non-destructive testing. Three Ir-192 sealed sources having radioactivity more than 50 Ci were made using research reactor HANARO of Korea Atomic Energy Research Institute. Tests were performed according to the leakage test criteria of domestic nuclear regulations and test standards of IAEA and ISO. As a test method, hot liquid immersion test was adopted to evaluate the leak activity of three Ir∼192 sealed sources having radioactivity of 56.2, 50.5, 51.2 Ci. Activities detected after immersion test of each sources showed 52.12, 9.71, 5.71 Bq and these values were very low compared to the safety criteria of sealed source leakage, 1,850 Bq(50 nCi). Through this study, it was verified that leak tightness and source capsule integrity of Ir-192 sealed NDT sources produced in HANARO

Part of:
Proceedings of the Korean Nuclear Society spring meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the Korean Nuclear Society spring meeting
Imprint Pagination
[ONE CDROM]
Journal Page Range
[9 p.]

Conference

Title
2001 spring meeting of the Korean Nuclear Society
Dates
24-25 May 2001
Place
Cheju (Korea, Republic of)

Optional Information

Notes
7 refs, 5 figs, 3 tabs