Published 1996 | Version v1
Journal article

Correction of dynamic error in on-line thickness measurement by gamma-ray transmission

  • 1. Qinghua Univ., Beijing, BJ (China)

Description

In on-line measurement on sheet thickness by gamma-ray transmission, for the sheet thickness vibrates in counting time, and attenuation of gamma-ray which penetrates matter follows an exponential law, not a linear one. So the measured value of thickness which is taken from mean counting rate deviates from the true value. The paper analyses the causes of this deviation, describes the expression form of the dynamic error which is induced by these deviatons, gives as method to diminish the dynamic error by correcting the deviation. (author). 1 ref

Part of:
Preparation of dysprosium-165/holmium-166 macro aggregate for radiation synovectomy

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
206
Journal Issue
2
Journal Page Range
p. 327-331.
ISSN
0236-5731
CODEN
JRNCDM

Conference

Title
International Conference on Isotopes.
Dates
7-12 May 1995.
Place
Beijing (China).

Optional Information