Published 1997 | Version v1
Journal article

Calculation of the personal dose equivalent, HP(10), for neutrons in the MIRD phantom

  • 1. Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

Description

The personal dose equivalent, Hp(10), was calculated in the anthropomorphic Mird phantom. Hp(10) is compared with the primarily limited quantities, the effective dose, E, and the effective dose equivalent, HE, computed in the same Monte Carlo run. The operational quantity, Hs1(10), in the ICRU slab was found to approximate Hp(10) for multidirectional incidences. All quantities were obtained with the same database. Also the correlation with the organ dose equivalent in the testes and thymus are given graphically. The dependence of Hp(10) on the location in the trunk is discussed briefly. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
70
Journal Issue
1-4
Journal Page Range
p. 387-390.
ISSN
0144-8420
CODEN
RPDODE

Conference

Title
8. symposium on neutron dosimetry.
Dates
13-17 Nov 1995.
Place
Paris (France).

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
28059016
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY; S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ANGULAR CORRELATION; COMPARATIVE EVALUATIONS; DOSE EQUIVALENTS; ENERGY DEPENDENCE; NEUTRON DOSIMETRY; PHANTOMS; RADIATION PROTECTION
Descriptors DEC
CORRELATIONS; DOSIMETRY; EVALUATION; MOCKUP; STRUCTURAL MODELS

Optional Information

Secondary number(s)
CONF--951119.