Published 2015 | Version v1
Journal article

Computed tomography evaluation of rotary systems on the root canal transportation and centering ability

  • 1. Universidade de Ribeirao Preto (UNAERP), SP (Brazil). Fac. de Odontologia
  • 2. Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Fac. de Odoentologia

Description

The endodontic preparation of curved and narrow root canals is challenging, with a tendency for the prepared canal to deviate away from its natural axis. The aim of this study was to evaluate, by cone-beam computed tomography, the transportation and centering ability of curved mesiobuccal canals in maxillary molars after biomechanical preparation with different nickel-titanium (NiTi) rotary systems. Forty teeth with angles of curvature ranging from 20° to 40° and radii between 5.0 mm and 10.0 mm were selected and assigned into four groups (n = 10), according to the biomechanical preparative system used: Hero 642 (HR), Liberator (LB), ProTaper (PT), and Twisted File (TF). The specimens were inserted into an acrylic device and scanned with computed tomography prior to, and following, instrumentation at 3, 6 and 9 mm from the root apex. The canal degree of transportation and centering ability were calculated and analyzed using one-way ANOVA and Tukey's tests (α = 0.05). The results demonstrated no significant difference (p > 0.05) in shaping ability among the rotary systems. The mean canal transportation was: -0.049 ± 0.083 mm (HR); -0.004 ± 0.044 mm (LB); -0.003 ± 0.064 mm (PT); -0.021 ± 0.064 mm (TF). The mean canal centering ability was: -0.093 ± 0.147 mm (HR); -0.001 ± 0.100 mm (LB); -0.002 ± 0.134 mm (PT); -0.033 ± 0.133 mm (TF). Also, there was no significant difference among the root segments (p > 0.05). It was concluded that the Hero 642, Liberator, ProTaper, and Twisted File rotary systems could be safely used in curved canal instrumentation, resulting in satisfactory preservation of the original canal shape. (author)

Additional details

Publishing Information

Journal Title
Brazilian Oral Research (Online)
Journal Volume
29
Journal Issue
1
Journal Page Range
p. 1-7
ISSN
1807-3107

INIS

Country of Publication
Brazil
Country of Input or Organization
Brazil
INIS RN
46032212
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPUTERIZED TOMOGRAPHY; DENTISTRY; EQUIPMENT; IMAGES; JAW; NICKEL ALLOYS; TEETH; TITANIUM ALLOYS
Descriptors DEC
ALLOYS; BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; MEDICINE; ORAL CAVITY; ORGANS; SKELETON; SKULL; TOMOGRAPHY; TRANSITION ELEMENT ALLOYS