Alternative method of inservice hydraulic testing of difficult to test pumps
Creators
Description
The pump test codes require that system resistance be varied until the independent variable (either the pump flow rate or differential pressure) equals its reference value. Variance from this fixed reference value is not specifically allowed. However, the design of many systems makes it impractical to set the independent variable to an exact value. Over a limited range of pump operation about the fixed reference value, linear interpolation between two points of pump operation can be used to accurately determine degradation at the reference value without repeating reference test conditions. This paper presents an overview of possible alternatives for hydraulic testing of pumps and a detailed discussion of the linear interpolation method. The approximation error associated with linear interpolation is analyzed. Methods to quantify and minimize approximation error are presented
Files
Additional details
Publishing Information
- Imprint Title
- Proceedings of the Third NRC/ASME Symposium on Valve and Pump Testing. Session 1A--Session 2C: Volume 1
- Imprint Pagination
- 532 p.
- Journal Page Range
- p. 485-492.
- Report number
- NUREG/CP--0137-Vol.1
Conference
- Title
- 3. ASME/NRC symposium on valve and pump testing.
- Dates
- 18-21 Jul 1994.
- Place
- Washington, DC (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 26033566
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS; S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- IN-SERVICE INSPECTION; NUCLEAR POWER PLANTS; PUMPS; REACTOR COMPONENTS; RISK ASSESSMENT; TESTING
- Descriptors DEC
- EQUIPMENT; INSPECTION; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS