First experiences with model based iterative reconstructions influence on quantitative plaque volume and intensity measurements in coronary computed tomography angiography
Creators
- 1. Conrad Research Center, University College Lillebelt, Niels Bohrs Allé 1, 5230 Odense M (Denmark)
- 2. Odense University Hospital Svendborg, Medical Research Department, Valdemarsgade 53, 5700 Svendborg (Denmark)
- 3. Medis Medical Imaging Systems B.V, Schuttersveld 9, 2300 AJ Leiden (Netherlands)
- 4. Leiden University Medical Center, Department of Radiology, Division of Image Processing, Albinusdreef 2, 2300 RC Leiden (Netherlands)
- 5. University of Southern Denmark, Centre of Health Economics Research, Campusvej 55, 5230 Odense M (Denmark)
- 6. Odense University Hospital, Department of Nuclear Medicine, Sdr. Boulevard 29, 5000 Odense C (Denmark)
- 7. Århus University Hospital, Department of Clinical Engineering, Brendstrupgaardsvej 100, 8200 Århus N (Denmark)
Description
Purpose: Investigate the influence of adaptive statistical iterative reconstruction (ASIR) and the model-based IR (Veo) reconstruction algorithm in coronary computed tomography angiography (CCTA) images on quantitative measurements in coronary arteries for plaque volumes and intensities. Methods: Three patients had three independent dose reduced CCTA performed and reconstructed with 30% ASIR (CTDIvol at 6.7 mGy), 60% ASIR (CTDIvol 4.3 mGy) and Veo (CTDIvol at 1.9 mGy). Coronary plaque analysis was performed for each measured CCTA volumes, plaque burden and intensities. Results: Plaque volume and plaque burden show a decreasing tendency from ASIR to Veo as median volume for ASIR is 314 mm3 and 337 mm3–252 mm3 for Veo and plaque burden is 42% and 44% for ASIR to 39% for Veo. The lumen and vessel volume decrease slightly from 30% ASIR to 60% ASIR with 498 mm3–391 mm3 for lumen volume and vessel volume from 939 mm3 to 830 mm3. The intensities did not change overall between the different reconstructions for either lumen or plaque. Conclusion: We found a tendency of decreasing plaque volumes and plaque burden but no change in intensities with the use of low dose Veo CCTA (1.9 mGy) compared to dose reduced ASIR CCTA (6.7 mGy & 4.3 mGy), although more studies are warranted. - Highlights: • Veo decrease plaque volumes and plaque burden using low-dose CCTA. • Moving from ASIR 30%, ASIR 60% to Veo did not appear to influence the plaque intensities. • Studies including larger sample size are needed to investigate the effect on plaque.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.radi.2016.08.003Additional details
Identifiers
- DOI
- 10.1016/j.radi.2016.08.003;
- PII
- S1078-8174(16)30056-6;
Publishing Information
- Journal Title
- Radiography (London 1995)
- Journal Volume
- 23
- Journal Issue
- 1
- Journal Page Range
- p. 77-79
- ISSN
- 1078-8174
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 49034529
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; BIOMEDICAL RADIOGRAPHY; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; CORONARIES; DOSES; IMAGES; ITERATIVE METHODS; PATIENTS
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CALCULATION METHODS; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; EVALUATION; MATHEMATICAL LOGIC; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.