Published November 2017 | Version v1
Journal article

Endobronchial brachytherapy with curative intent: the impact of reference points setting according to the bronchial diameter

  • 1. Mie University Hospital, Department of Radiation Oncology, 2–174 Edobashi, Tsu, Mie 514-8507 (Japan)
  • 2. Mie University, Department of Radiation Oncology, Graduate School of Medicine, 2–174 Edobashi, Tsu, Mie 514-8507 (Japan)
  • 3. Department of Radiology, Matsusaka Central Hospital, 102 Kobou Kawai-machi, Matsusaka, Mie, 515-8566 (Japan)
  • 4. Mie University, Department of Radiology, Graduate School of Medicine, 2–174 Edobashi, Tsu, Mie 514-8507 (Japan)

Description

Endobronchial brachytherapy (EBB) is an effective treatment for endobronchial tumors. However, bronchial toxicity caused by over-irradiation remains problematic. To decrease bronchial toxicity, we developed a source-centralizing applicator for EBB. The purpose of the present study was to assess the efficacy and safety of EBB with varying reference dose points according to the bronchial diameter, using a source-centralizing applicator. We reviewed 15 patients with endobronchial carcinoma who were treated with curative intent using a combination of external beam radiotherapy (EBRT) and high-dose-rate EBB between 2005 and 2014. During each EBB session, we used a source-centralizing applicator that maintained the source-delivering catheter in the center of the bronchial lumen. Reference dose points were 5–7 mm from the source axis, depending on the bronchial diameter. The median radiation doses of EBRT and EBB were 40 Gy in 20 fractions and 18 Gy in 3 fractions, respectively. The median observation period was 36 months. The 3-year overall survival, progression-free survival and local control rates were 79%, 77% and 100%, respectively. Grade 2 radiation pneumonitis was observed in two cases. Bronchial toxicities, such as hemoptysis or the symptoms of chronic bronchitis, were not observed. EBB with varying reference dose points according to bronchial diameter, using a source-centralizing applicator, is a promising procedure that may be effective for tumor elimination and reducing toxicity to the bronchial wall.

Availability note (English)

Available from http://dx.doi.org/10.1093/jrr/rrx031; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5710514

Additional details

Identifiers

Publishing Information

Journal Title
Journal of Radiation Research
Journal Volume
58
Journal Issue
6
Journal Page Range
p. 849-853
ISSN
0449-3060

INIS

Country of Publication
Japan
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
49049954
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BRACHYTHERAPY; EXTERNAL BEAM RADIATION THERAPY; GY RANGE 10-100; IRRADIATION; NEOPLASMS; RADIATION DOSES; TOXICITY
Descriptors DEC
ABSORBED DOSE RANGE; DISEASES; DOSES; GY RANGE; MEDICINE; NUCLEAR MEDICINE; RADIATION DOSE RANGES; RADIOLOGY; RADIOTHERAPY; THERAPY

Optional Information

Copyright
Copyright (c) The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.
Notes
PMCID: PMC5710514; PMID: 29106573; PUBLISHER-ID: rrx031; OAI: oai:pubmedcentral.nih.gov:5710514