Published 2008 | Version v1
Miscellaneous Open

Radiocromic film, TLD, OSL and 'Paracas Phantom' by dosimetric intercomparation in stereotactic radiosurgery

Description

Full text: In Peru, one deals to patients with arteriovenous malformations or cerebral tumors by means of stereotactic radiosurgery, using fine photon beams of high energy of 6 MeV, generated by a linear accelerator Varian 2100 Clinac CD of the Complejo Hospitalario San Pablo in Lima, Peru. In this work we describes the 'Dosimetric Intercomparation System of the Quality Assurance Program in Stereotactic Radiosurgery of the Complejo Hospitalario San Pablo (DIS)'. The DIS allows to guarantee application of the doses with high accuracy. It shows the good performance of the Local DIS's components: dosimetry of radiocromics films, dosimetry termoluminiscent (TLD), dosimetry of optically stimulated luminescence (OSL) and an anthropomorphic phantom of head constructed locally, denominated 'Paracas Phantom'. Also, in the International DIS practiced with The University of Texas Md Anderson Cancer Center, stands out results within the ranges: a) Dose to the center of the target (RDS/Institution): 0,95-1,05; b) Treated volumen (Measured/Institution): 0,75 - 1,05; c) Ratio of measure treated volume to target volume: 1,00 - 2,00; and d) Minimum dose to target (Minimum dose/Prescription dose): >0,90. It concludes that the DIS is important for the good decision making on the radiological safety of the patients dealt with stereotactic radiosurgery. (author)

Availability note (English)

Available from INIS in electronic form

Files

40108740.pdf

Files (35.4 kB)

Name Size Download all
md5:eda6cbff0de062ec06ad2863f50c5d46
35.4 kB Preview Download

Additional details

Publishing Information

Publisher
SAR
Imprint Place
Buenos Aires (Argentina)
Imprint Pagination
1 p.
Report number
INIS-AR-C--741

Conference

Title
12. International congress of the International Radiation Protection Association (IRPA): Strengthening radiation protection worldwide
Acronym
IRPA 12
Dates
19-24 Oct 2008
Place
Buenos Aires (Argentina)

INIS

Country of Publication
Argentina
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
40108740
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CEREBRAL ARTERIES; FILM DOSIMETRY; HEAD; LINEAR ACCELERATORS; MALFORMATIONS; NEOPLASMS; PHANTOMS; PHOTON BEAMS; QUALITY ASSURANCE; RADIATION DOSES; RADIATION PROTECTION; RADIOTHERAPY; SURGERY; THERMOLUMINESCENT DOSIMETRY
Descriptors DEC
ACCELERATORS; ARTERIES; BEAMS; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DISEASES; DOSES; DOSIMETRY; MEDICINE; MOCKUP; NUCLEAR MEDICINE; ORGANS; PATHOLOGICAL CHANGES; RADIOLOGY; STRUCTURAL MODELS; THERAPY

Optional Information

Notes
Oral presentation; Abstract only