Published December 2011 | Version v1
Journal article

Measurements of control rod worth by modified inverse kinetic method

  • 1. Russian Research Centre Kurchatov Institute (Russian Federation)

Description

Results of control rod worth measurements on the Astra critical assembly at the Russian Research Centre Kurchatov Institute are presented. The measurements were carried out by the modified inverse kinetics method, which is based on the use of experimental information about the variation of neutron detector readings only after introducing a reactivity perturbation. Calculated corrections are not required. The results of measurements do not depend on the neutron detector position.

Additional details

Identifiers

Publishing Information

Journal Title
Physics of Atomic Nuclei
Journal Volume
74
Journal Issue
14
Journal Page Range
p. 1917-1920
ISSN
1063-7788
CODEN
PANUEO

Optional Information

Copyright
Copyright (c) 2011 Pleiades Publishing, Ltd.