Bone mass measurement improvement in micro-CT taking into account the physical phenomena

Description

Due to the increased survival of the patients with cystic fibrosis (CF), studies showed the presence of osteoporosis in CF patients. In this work, a follow-up study of the bone mineral density (BMD) for mice with CF is done using a micro-CT system. In order to perform accurately the measurements, we applied two correction methods aiming to reduce artifacts in CT images. The first correction method is a beam hardening correction technique based on a post-reconstruction procedure and using pre-calculated linearization curves. The second correction method is a hybrid elimination approach of scatter radiations from acquisition projections and based on the use of pre-calculated scatter kernels, simulated analytically. Improvements have been shown concerning image quality (contrast, artifacts reduction) and BMD measurements. (author)

Abstract (French)

Suite a l'allongement de la survie des patients atteints de la mucoviscidose (CF), des etudes ont montre la presence d'une perte osseuse chez les patients CF. Dans ce travail de these, une etude de l'evolution de la densite minerale osseuse chez des souris atteintes de mucoviscidose a ete effectuee en utilisant un systeme de micro-tomodensitometrie X. Afin d'ameliorer les precisions des mesure, deux methodes de correction de deux phenomenes physiques ont ete appliquees. La premiere methode est une correction du durcissement de faisceau X et basee sur une segmentation de l'objet reconstruit apres une premiere reconstruction et en utilisant des courbes d'attenuations precalculees. La deuxieme methode est une methode de correction de la diffusion des rayons dans l'animal basee sur l'estimation des projections des diffuses en utilisant des noyaux de diffusion precalculees. Des ameliorations au niveau de la qualite de l'image et les mesures de densite osseuses ont ete obtenues. (auteur)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Original title (French)
Amelioration du calcul de la masse osseuse par micro-tomodensitometrie X: prise en compte des phenomenes physiques

Publishing Information

Imprint Pagination
148 p.
Report number
FRNC-TH--13910

Optional Information

Notes
122 refs.; Available from the INIS Liaison Officer for France, see the INIS website for current contact and E-mail addresses