Published 1988 | Version v1
Report

One-inch UF6 cylinder valve failure

  • 1. Martin Marietta Energy Systems, Inc., Paducah, KY (USA)

Description

Defects in one-inch cylinder valves procured for use in uranium hexafluoride (UF6) cylinders were discovered during installation. The defects were detected by soap testing of the valves and cylinders. The investigation detected similar problems in other production runs by the same manufacturer. This paper covers the investigation of the original problem, evaluation of the defects, notification of all concerned parties, interim solution, and corrective actions taken to eliminate this problem

Additional details

Publishing Information

Imprint Title
Uranium hexafluoride: Safe handling, processing, and transporting: Conference proceedings
Imprint Pagination
239 p.
Journal Page Range
p. 171-177.
Report number
CONF-880558--

Conference

Title
Uranium hexafluoride--safe handling, processing, and transporting conference.
Dates
24-26 May 1988.
Place
Oak Ridge, TN (USA).