Published 1982 | Version v1
Journal article

Crack detection with an eddy-current probe integrated into an endoscope

  • 1. Allianz-Zentrum fuer Technik G.m.b.H. (AZT), Ismaning (Germany, F.R.). Fachbereich Physikalische Messtechnik

Description

Objective and quantitive crack detection in inaccessible machine internals is possible without dismantling the equipment through the combination of endoscopic and eddy-current techniques, whereby the endoscope is used both as an optical and a mechanical manipulator. Thus the availability of machinery can be increased and the overhaul costs lowered. The integrated endoscope/eddy-current probe should be utilised whenever normal endoscopic inspection indicates a possible crack location which cannot be assessed definitively through visual observation alone. Its use is also advantageous in monitoring crack propagation within a component. (orig.)

Abstract (German)

Durch die Kombination von Endoskopie und Wirbelstromverfahren, wobei das Endoskop als optisch-mechanischer Manipulator verwendet wird, ist eine objektive, quantitative Risspruefung in unzugaenglichen Innenraeumen ohne Demontage der Anlage durchfuehrbar. Dadurch koennen die Verfuegbarkeit einer Maschine erhoeht und die Revisionskosten gesenkt werden. Die endoskopgefuehrte Wirbelstromsonde sollte immer dann eingesetzt werden, wenn bei einer Endoskopinspektion eine rissverdaechtige Stelle beobachtet wird, die aber durch die rein optische Betrachtung nicht eindeutig erkannt werden kann. Vorteilhaft ist der Einsatz auch bei der Rissfortschrittsueberwachung eines Bauteiles. (orig.)

Additional details

Additional titles

Original title (German)
Risspruefung mit einer endoskopgefuehrten Wirbelstromsonde

Publishing Information

Journal Title
Maschinenschaden
Journal Volume
55
Journal Issue
2
Series
Maschinenschaden.
Journal Page Range
128-131
ISSN
0025-4517