Published April 1996 | Version v1
Journal article

Application of the cumulative sum algorithm for steam generator leakage detection

  • 1. Gosudarstvennyj Nauchnyj Tsentr Rossijskoj Federatsii - Fiziko-Ehnergeticheskij Inst., Obninsk (Russian Federation)

Description

Consideration is given to the problem of revealing minor effects of failure of heat-exchange surfaces in steam generators of sodium-water type according to fluctuation signals of regular magnetic flowmeters. Monitoring of fluctuation signals of magnetic flowmeters was based on auto-regression simulation and modified algorithm of cumulative sums. Good results were obtained for experiments with gas injection at bench and commercial plants. 3 refs., 3 figs

Additional details

Additional titles

Original title (Russian)
Применение алгоритма кумулятивных сумм для обнаружения протечек парогенераторов

Publishing Information

Journal Title
Atomnaya Ehnergiya
Journal Volume
80
Journal Issue
4
Journal Page Range
p. 252-257.
ISSN
0004-7163
CODEN
AENGAB