Published March 2012 | Version v1
Journal article

The Review of Exposure Index in Digital Radiography and Image Quality

  • 1. Dept. of Radiology, Dongshin university, Naju (Korea, Republic of)
  • 2. Dept. of Radiation Technology Gwangju Health University, Gwangju (Korea, Republic of)

Description

The aim of this study was to determine the correlation between exposure index (EI) and dose factors related to radiation dose optimization in digital radiography (DR) system. Two phantoms with built-in regional test object for quantitative assessment of images were used to produce image signals that acquired in chest radiography background. EI and entrane surface dose (ESD) increased proportionally with rise of radiation dose (kVp, mAs) in both DR and CR systems. Especially, DR detector was effective to form good contrast and hence, reached easily to improvement of image quality with minimal dose changes. It made operators possible to expect the accuracy of EI values deeply related to absorbed dose of the detector. The evaluation of images was obtained specially employed calculation of noise to signal ratio (NSR) and contrast to noise ratio (CNR). These measurements were performed for how exposure factors affect image quality. NSR was inversely proportional to kVp and mAs and low NSR represented high signal detection efficiency. Consequently, EI values was the measure of the amount of exposure received by the image receptor and it was proportional to exposure factors. Therefore the EI in a recommended range from manufacturer can offer optimal image quality. Also, continuous monitoring of EI values in the digital radiography can reduce the unnecessary patient dose and help the quality control of the system.

Additional details

Publishing Information

Journal Title
Journal of Radiation Protection
Journal Volume
38
Journal Issue
1
Series
14 refs, 5 figs, 3 tabs
Journal Page Range
p. 29-36
ISSN
0253-4231

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
50081801
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
CORRELATIONS; IMAGES; MONITORING; QUALITY CONTROL; RADIATION DOSES; RECOMMENDATIONS; REDUCTION; SIGNALS; SURFACES
Descriptors DEC
CHEMICAL REACTIONS; CONTROL; DOSES