Published January 1994 | Version v1
Journal article

A new SSNTD method for the measurement of radon - thoron mixed working levels in dwellings

  • 1. Bhabha Atomic Research Centre, Bombay (India). Environmental Assessment Div.

Description

A new method has been developed for the time-integrated measurement of radon and thoron working levels in air using solid state nuclear track detector (SSNTD). The standardisation procedure used Kodak LR 115 films and the results obtained are briefly outlined. The overall error of this method of measurement works out to be about ±30 per cent. Field trials are carried out in monazite areas of Kerala using this technique. (author). 2 refs., 3 figs

Additional details

Publishing Information

Journal Title
Bulletin of Radiation Protection
Journal Volume
17
Journal Issue
1
Journal Page Range
p. 34-35.
ISSN
0253-6897
CODEN
BRPRDN