Published September 1997 | Version v1
Report

Safety analyses of accidents for the new fuel at the Dukovany NPP. Uncontrolled opening of the steam dump valve to the condenser. Revision 1

Description

The case of uncontrolled opening of all steam dump valves to the condenser was analyzed with respect to ensuring a sufficient cooling of the reactor core; therefore, the conservative assumptions were chosen so as to attain the lowest possible departure from nucleate boiling ratio (DNBR). The RELAP5/MOD3.1 code was employed. The acceptance criteria for the accident were met

Availability note (English)

Available from Nuclear Research Institute Rez, 250 68 Rez, Czech Republic

Additional details

Additional titles

Original title (Czech)
Bezpecnostni analyzy havarii pro nove palivo JE Dukovany - nerizene otevreni PSK. Revize 1

Publishing Information

Imprint Pagination
56 p.
Report number
UJV--11000-T

Optional Information

Notes
4 tabs., 29 figs., 10 refs.