Published November 1998
| Version v1
Report
Performance of the PLS storage ring vacuum system
Creators
- 1. Pohang Inst. of Science and Technology, Pohang Accelerator Lab., kyungbuk (Korea, Republic of)
Description
The ultra-high vacuum system of the PLS electron storage ring has been operated since September 1994. Beam-on pressures of ∼1x10-9 Torr have been maintained and beam lifetimes in excess of 15 hours with 200 mA of stored beam at 2 GeV are regularly obtained. The beam-gas lifetime was measured using helium gas and the results are in good agreement with the calculated ones. This paper describes the performance and the experience obtained during the installation and operation of the vacuum system (author)
Additional details
Identifiers
- URL
- http://www.kek.jp;
Publishing Information
- Imprint Title
- Proceedings of the first Asian particle accelerator conference (APAC98)
- Imprint Pagination
- 960 p.
- Journal Page Range
- p. 277-279
- Report number
- KEK-PROC--98-10
Conference
- Title
- 1. Asian particle accelerator conference
- Acronym
- APAC98
- Dates
- 23-27 Mar 1998
- Place
- Tsukuba, Ibaraki (Japan)
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 31007217
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ELECTRON BEAMS; LEAKS; LIFETIME; PERFORMANCE; STORAGE RINGS; SYNCHROTRON RADIATION SOURCES; ULTRAHIGH VACUUM; VACUUM SYSTEMS
- Descriptors DEC
- BEAMS; LEPTON BEAMS; PARTICLE BEAMS; RADIATION SOURCES