Parametric optimization of the MVC desalination plant with thermomechanical compressor
- 1. Heat Engineering and Heat Engines Department, Samara National Research University, Samara (Russian Federation)
Description
This article deals with parametric optimization of the Mechanical Vapour Compression (MVC) desalination plant with thermomechanical compressor. In this plants thermocompressor is used instead of commonly used centrifugal compressor. Influence of two main parameters was studied. These parameters are: inlet pressure and number of stages. Analysis shows that it is possible to achieve better plant performance in comparison with traditional MVC plant. But is required reducing the number of stages and utilization of low or high initial pressure with power consumption maximum at approximately 20-30 kPa. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1757-899X/339/1/012032Additional details
Identifiers
Publishing Information
- Journal Title
- IOP Conference Series. Materials Science and Engineering (Online)
- Journal Volume
- 339
- Journal Issue
- 1
- Journal Page Range
- [6 p.]
- ISSN
- 1757-899X
Conference
- Title
- 2. International Conference on Mechatronics and Electrical Systems
- Acronym
- ICMES 2017
- Dates
- 15-17 Dec 2017
- Place
- Wuhan (China)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 52089369
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COMPARATIVE EVALUATIONS; COMPRESSION; COMPRESSORS; DESALINATION PLANTS; OPTIMIZATION; PERFORMANCE; VAPORS
- Descriptors DEC
- EVALUATION; FLUIDS; GASES; INDUSTRIAL PLANTS