Published April 1981 | Version v1
Report Open

Dose measurements of x-ray radiation from JIPP T-II device in the vicinity of Water Research Institute, Nagoya University

Description

Spatial distribution of X-ray doses from JIPP T-II, a hybrid device of tokamak and stellarator at the Institute of Plasma Physics, has been measured with thermoluminescence dosimeter (TLD). The increment in the dose, to which JIPP T-II is responsible, is discriminating from natural doses only at non-shielded regions of the Water Research Institute (WRI) which is located 36 m apart from JIPP T-II device. By controlling the operation of JIPP T-II, an intergrated value of the increment measured with ionization chamber at the windowside of the second floor, WRI, has been kept below 100 μrem during a week, according to the regulation of Nagoya University. The doses at the non-shielded region of WRI are expected to decrease to one-fifth of the present value with a shield (20 mm thick lead panels) which will be completed by the end of February 1981. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

13683961.pdf

Files (393.2 kB)

Name Size Download all
md5:94f2756727cea114872e3b70954e68b2
393.2 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
12 p.
Report number
IPPJ-DT--85