Dose measurements of x-ray radiation from JIPP T-II device in the vicinity of Water Research Institute, Nagoya University
Description
Spatial distribution of X-ray doses from JIPP T-II, a hybrid device of tokamak and stellarator at the Institute of Plasma Physics, has been measured with thermoluminescence dosimeter (TLD). The increment in the dose, to which JIPP T-II is responsible, is discriminating from natural doses only at non-shielded regions of the Water Research Institute (WRI) which is located 36 m apart from JIPP T-II device. By controlling the operation of JIPP T-II, an intergrated value of the increment measured with ionization chamber at the windowside of the second floor, WRI, has been kept below 100 μrem during a week, according to the regulation of Nagoya University. The doses at the non-shielded region of WRI are expected to decrease to one-fifth of the present value with a shield (20 mm thick lead panels) which will be completed by the end of February 1981. (author)
Availability note (English)
MF available from INIS under the Report Number.Files
13683961.pdf
Files
(393.2 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:94f2756727cea114872e3b70954e68b2
|
393.2 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 12 p.
- Report number
- IPPJ-DT--85
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 13683961
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- JIPP STELLARATOR; RADIATION DETECTION; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; RADIATION MONITORING; RADIATION PROTECTION; SPATIAL DISTRIBUTION; THERMOLUMINESCENT DOSEMETERS; X-RAY DOSIMETRY
- Descriptors DEC
- CLOSED PLASMA DEVICES; DISTRIBUTION; DOSEMETERS; DOSIMETRY; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MONITORING; STELLARATORS; THERMONUCLEAR DEVICES