Published March 1986
| Version v1
Journal article
The reactor containment of standard-design German pressurized water reactors
- 1. Kraftwerk Union AG, Postfach 3220, D-8520 Erlangen
Description
A survey of the engineered design of the containment of a standard German pressurized water reactor of the 1300-MW(electric) category is presented. One essential part of the containment consists of a 4-cm-thick and 56-m-diam detached steel shell, surrounded by a 2-m-thick concrete shielding. Between the concrete shell and the containment, an annulus has been provided that can be vented via filters under accident conditions. In numerous experiments, the extraordinarily conservative approach in the layout of the structure has been proved to withstand the loss-of-coolant design-basis accident. This conservative approach in design also has positive effects in restricting the consequences of a core meltdown accident
Additional details
Publishing Information
- Journal Title
- Nucl. Technol.
- Journal Volume
- 72
- Journal Issue
- 3
- Series
- Nucl. Technol.
- Journal Page Range
- vp
- ISSN
- 0029-5450
- CODEN
- NUTYB
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 17051775
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CONCRETES; CONTAINMENT; CONTAINMENT SHELLS; DESIGN BASIS ACCIDENTS; FEDERAL REPUBLIC OF GERMANY; FILTERS; HEAT TRANSFER; HYDRAULICS; LOSS OF COOLANT; MELTDOWN; PWR TYPE REACTORS; SHIELDING; SPECIFICATIONS
- Descriptors DEC
- ACCIDENTS; BUILDING MATERIALS; DEVELOPED COUNTRIES; ENERGY TRANSFER; ENRICHED URANIUM REACTORS; EUROPE; MATERIALS; POWER REACTORS; REACTOR ACCIDENTS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS