Published August 2013 | Version v1
Report

Seismic and tsunami safety margin assessment

Description

Nuclear Regulation Authority is going to establish new seismic and tsunami safety guidelines to increase the safety of NPPs. The main purpose of this research is testing structures/components important to safety and tsunami resistant structures/components, and evaluating the capacity of them against earthquake and tsunami. Those capacity data will be utilized for the seismic and tsunami back-fit review based on the new seismic and tsunami safety guidelines. The summary of the program in 2012 is as follows. 1. Component seismic capacity test and quantitative seismic capacity evaluation. PWR emergency diesel generator partial-model seismic capacity tests have been conducted and quantitative seismic capacities have been evaluated. 2. Seismic capacity evaluation of switching-station electric equipment. Existing seismic test data investigation, specification survey and seismic response analyses have been conducted. 3. Tsunami capacity evaluation of anti-inundation measure facilities. Tsunami pressure test have been conducted utilizing a small breakwater model and evaluated basic characteristics of tsunami pressure against seawall structure. (author)

Part of:
Annual safety research report, JFY 2012

Additional details

Publishing Information

Imprint Title
Annual safety research report, JFY 2012
Imprint Pagination
708 p.
Journal Page Range
p. 131-140
Report number
JNES-RE--2013-0001-Rev.1

Optional Information

Notes
3 refs., 17 figs., 4 tabs.; This record replaces 46066579