Construction and operation of an improved radiation calibration facility at Brookhaven National Laboratory. Environmental assessment
Description
Calibration of instruments used to detect and measure ionizing radiation has been conducted over the last 20 years at Brookhaven National Laboratory's (BNL) Radiation Calibration Facility, Building 348. Growth of research facilities, projects in progress, and more stringent Department of Energy (DOE) orders which involve exposure to nuclear radiation have placed substantial burdens on the existing radiation calibration facility. The facility currently does not meet the requirements of DOE Order 5480.4 or American National Standards Institute (ANSI) N323-1978, which establish calibration methods for portable radiation protection instruments used in the detection and measurement of levels of ionizing radiation fields or levels of radioactive surface contaminations. Failure to comply with this standard could mean instrumentation is not being calibrated to necessary levels of sensitivity. The Laboratory has also recently obtained a new neutron source and gamma beam irradiator which can not be made operational at existing facilities because of geometry and shielding inadequacies. These sources are needed to perform routine periodic calibrations of radiation detecting instruments used by scientific and technical personnel and to meet BNL's substantial increase in demand for radiation monitoring capabilities. To place these new sources into operation, it is proposed to construct an addition to the existing radiation calibration facility that would house all calibration sources and bring BNL calibration activities into compliance with DOE and ANSI standards. The purpose of this assessment is to identify potential significant environmental impacts associated with the construction and operation of an improved radiation calibration facility at BNL
Availability note (English)
MF available from INIS under the Report Number; Also available from OSTI as DE95012129; NTIS; US Govt. Printing Office Dep.Files
27005974.pdf
Files
(921.7 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:d27d547f6f42bc60191989137c6f8545
|
921.7 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 25 p.
- Report number
- DOE/EA--0891
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 27005974
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S42: ENGINEERING;
- Descriptors DEI
- CALIBRATION; DOSE RATES; ENERGY FACILITIES; IONIZING RADIATIONS; RADIATION DETECTORS; SITE SELECTION
- Descriptors DEC
- MEASURING INSTRUMENTS; RADIATIONS
Optional Information
- Funding organization
- USDOE, Washington, DC (United States).