Published January 1991 | Version v1
Journal article

A method for determination of hydrogen content in uranium dioxide samples using a semiconductor sensor

  • 1. Vsesoyuznyj Nauchno-Issledovatel'skij Inst. Neorganicheskikh Materialov, Moscow (USSR)
  • 2. Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Moscow (USSR). Inst. Atomnoj Ehnergii

Description

Measurements of H2 content in UO2 samples were carried out on the basis of a technique using a hydrogen sensitive sensor of Pd-SiO2-Si. A specially made set-up allowed to register the amount of H2 in UO2 samples up to 10-10 g. Measured H2 content in investigated samples was 8.32 and 102 ppb (mass) at 400, 800 and 1600 deg C, respectively. (author) 3 figs

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
147
Journal Issue
1
Series
J. Radioanal. Nucl. Chem. ;Articles.
Journal Page Range
197-200
ISSN
0236-5731
CODEN
JRNCD

Conference

Title
International conference on Actinides - 89.
Dates
24-29 Sep 1989.
Place
Tashkent (USSR).