Published December 1975 | Version v1
Journal article

Experience of research, design, capacity, and operation with forced flow steam generators

  • 1. Babcock and Wilcox Co., Lynchburg, Va. (USA). Nuclear Power Generation Div.
  • 2. Babcock and Wilcox Co., Alliance, Ohio (USA). Research and Development Div.

Description

The forced flow steam generators in operation in six American nuclear power plants show an excellent operational behaviour. The concept for this type of steam generator has been developed in the USA, and it has been successfully tested over several years regarding its suitability for PWRs of a larger size. The results concerning construction, materials and water chemistry for this steam generator, which will be used for the first time in the FRG in the nuclear power station Muelheim-Kaerlich, have confirmed the high reliability of this high-efficiency component. (orig./LN)

Abstract (German)

Die in sechs amerikanischen Kernkraftwerken in Betrieb befindlichen Zwangsdurchlauf-Dampferzeuger weisen ein ausgezeichnetes Betriebsverhalten auf. Das Konzept zu diesem Dampferzeuger-Typ wurde in den USA entwickelt und in mehrjaehrigen Versuchsreihen auf seine Eignung fuer den Einsatz in grossen Druckwasserreaktoren erfolgreich erprobt. Die Ergebnisse hinsichtlich Konstruktion, Werkstoffe und Wasserchemie fuer diesen Dampferzeuger, der erstmals in der BRD im Kernkraftwerk Muelheim-Kaerlich zur Anwendung kommt, haben die grosse Zuverlaessigkeit dieser Hochleistungskomponente bestaetigt. (orig.)

Additional details

Additional titles

Original title (German)
Forschungs-, Auslegungs-, Leistungs- und Betriebserfahrungen mit Zwangsdurchlauf-Dampferzeugern

Publishing Information

Journal Title
Brennst.-Waerme-Kraft
Journal Volume
27
Journal Issue
12
Series
Brennst.-Waerme-Kraft.
Journal Page Range
459-465

INIS

Optional Information

Notes
7 figs.; 5 tabs.; 5 refs.