Influence of temperature on strain monitoring of degradation in concrete containment buildings

  • 1. Atomic Energy of Canada Limited - AECL, 1 Plant Road, Chalk River, K0J 1J0, ON (Canada)

Description

Concrete containment buildings (CCBs) are important safety structures in a nuclear power plant (NPP). The CCBs can be made of reinforced and post-tensioned (P-T) concrete. Post-tensioning concrete induces compressive stresses, which have to be overcome for the concrete to crack under tensile loads. However, post-tensioned CCBs may undergo pre-stressing losses as they age, which could affect their performance under accident conditions. CANDU 6 reactor buildings contain grouted post-tensioned tendons as the primary reinforcement. The grouting of the tendons makes direct monitoring of pre-stressing losses via lift-off testing impossible. Therefore, instruments have been installed on an existing reactor building to measure and monitor strains and stresses in the concrete and the deformation of the concrete structure to detect aging degradation and indirectly evaluate the pre-stressing losses. However, the instrumentation readings are affected by temporary volume changes in the concrete caused by the influence of environmental factors, particularly temperature, on concrete. In this work, the focus is on developing an understanding of the effect of temperature on the interpretation of instrumentation data from a reactor building. Vibrating Wire Strain Gauge (VWSG) data has been analysed. The influence of concrete coefficient of thermal expansion and temperature distribution within the reactor building walls, on VWSG data, is discussed based on the analysis of the available instrumentation data and available numerical simulation results. The present study demonstrates that temperature distribution within the containment concrete has a significant impact on the VWSG measurements and the coefficient of thermal expansion of concrete is an important factor in the correction of VWSG data for thermal strain. It is recommended that VWSG data obtained over small temperature variations be considered for interpretation to assess pre-stressing losses. (authors)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
27 p.
Report number
INIS-FR--15-0430

Conference

Title
Conference on Contribution of Materials Investigations and Operating Experience to LWRs' Safety, Performance and Reliability
Acronym
Fontevraud 8
Dates
15-18 Sep 2014
Place
Avignon (France)

Optional Information

Notes
9 refs.; Available from the INIS Liaison Officer for France, see the 'INIS contacts' section of the INIS website for current contact and E-mail addresses: http://www.iaea.org/INIS/contacts/