Published August 2016 | Version v1
Journal article

Transient characteristics of main feedwater line rupture accident for AP1000 nuclear power plant

  • 1. Nuclear Safety Regulatory Department II, Ministry of Environmental Protection, Beijing (China)
  • 2. China Institute of Atomic Energy, Beijing (China)
  • 3. Nuclear and Radiation Safety Center, Ministry of Environmental Protection, Beijing (China)

Description

The AP1000 is the typical 'third generation' passive nuclear power plant in the world at present. The primary system of AP1000 nuclear power plant was modeled using RELAP5/MOD3.3 code, and the transient thermal-hydraulic characteristics and the response characteristics of passive system were analyzed under the accident sequence of main feedwater line rupture accident. The results show that during the accident, the primary loop pressure, secondary loop pressure and primary loop temperature are fluctuant. The RCS pressure maximum value is 17.13 MPa, less than 91% of the design pressure. The pressure of the main steam system is also less than 91% of the designed value, which satisfies acceptance criteria. (authors)

Additional details

Identifiers

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
50
Journal Issue
8
Journal Page Range
p. 1422-1427
ISSN
1000-6931

Optional Information

Notes
4 figs., 1 tab., 9 refs.; http://dx.doi.org/10.7538/yzk.2016.50.08.1422