Published 2004 | Version v1
Report

Evaluation and database of ko-standardization neutron activation analysis system

  • 1. Tokyo Univ., Research Center of Nuclear Science and Technology, Tokyo (Japan)

Description

It is very important to clear the neutron characteristics of the irradiation field accurately to use the ko standardization neutron activation analysis method. The irradiation parameter of JRR-4 was measured. Au, Zr, and Al used for the parameter measurement in the ko method were irradiated and the radioactivity of Al-28, Au-198, Zr-95, and Zr-97 was measured. When the control rod was positioned in the operating time of six hours for the output adjustment, the change of the neutron flux that exceeded 10% was observed. Therefore, it has been understood that the determination of irradiation parameter that used the monitor whenever irradiating it is necessary. (H. Katsuta)

Part of:
Report on progress of researches by common utilization of JAERI nuclear facilities, for fiscal 2002

Additional details

Publishing Information

Imprint Title
Report on progress of researches by common utilization of JAERI nuclear facilities, for fiscal 2002
Imprint Pagination
251 p.
Journal Page Range
p. 188-194
Report number
UTRCN-G--32

Optional Information

Notes
3 refs., 5 figs., 5 tabs.