TRAC analysis of the effect of increased ECC subcooling on the reflood transient in the Slab Core Test Facility

Description

A blind posttest calculation of Slab Core Test Facility (SCTF) Run 510, the high-subcooling test, was completed with TRAC-PD2/MOD1 using initial conditions provided by the Japan Atomic Energy Research Institute (JAERI), but without knowledge of the actual test results. There is good comparison between the calculation and the data for rod temperatures, turnaround times, core differential pressures, and mass inventories, and reasonable comparison for absolute pressures, upper plenum pool formation, and fluid temperatures and mass accumulation in the steam-water separator. Comparison of this calculation with the calculation of the base case test (Run 507) shows that the qualitative behavior during reflood is calculated correctly for both cases. In addition, from this comparison the following conclusions can be drawn: for the high-subcooling case, the peak rod temperture was lower, calculated quench times were earlier, there was more entrainment and liquid carryover from the core to the upper plenum, and the liquid mass accumulation in both the core and the upper plenum was greater

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01 as DE82015739.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
PWR

Publishing Information

Imprint Pagination
16 p.
Report number
LA-UR--82-1438

Conference

Title
ANS topical meeting.
Dates
22 - 24 Sep 1982.
Place
Niagara Falls, NY (USA).

Optional Information