Published February 1979 | Version v1
Journal article

Investigation of measuring accuracy of automatic plugging indicator

  • 1. Hitachi Ltd., Ibaraki (Japan). Energy Research Lab.

Description

In order to improve the measuring accuracy of plugging indicators, the relation between the measured temperature and the impurity saturation temperature was investigated analytically for the oscillating plugging indicator. In the analysis, the differences between the true saturation temperature and the ''plugging'' or ''unplugging'' temperature were studied in view of the impurity precipitating mechanism. By this investigation, the difference of measured temperature from the saturation temperature can be evaluated by a function of the dimensionless numbers Re and St and the suitable operating conditions on which the measurement error becomes small are obtained. (author)

Additional details

Publishing Information

Journal Title
J. Nucl. Sci. Technol. (Tokyo)
Journal Volume
16
Journal Issue
2
Series
J. Nucl. Sci. Technol. (Tokyo).
Journal Page Range
109-116
ISSN
0022-3131

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
11514524
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Numerical Data
Descriptors DEI
ACCURACY; AUTOMATION; CLOSURES; ERRORS; EXPERIMENTAL DATA; FLOW RATE; GRAPHS; IMPURITIES; INDICATORS; REYNOLDS NUMBER; SODIUM; SOLUBILITY; TEMPERATURE DEPENDENCE
Descriptors DEC
ALKALI METALS; DATA; DATA FORMS; ELEMENTS; INFORMATION; METALS; NUMERICAL DATA