Published July 10, 1992 | Version v1
Journal article

The APS linac beam position monitors and electronics

  • 1. Argonne National Laboratory, Argonne, Illinois 60439 (United States)

Description

Beam position monitors using stripline pickups for 30 ns long electron and positron beam bunches have been built and responses were measured in the vertical and horizontal directions. Log amplifiers used for signal processing have a dynamic range of 40 dB and are scaled for 50 mV/dB sensitivity. In this paper we describe the design of the detectors, the signal processing electronics, and the results of the position-to-signal mapping using a wire. Beam position measurements using a prototype detector and electronics on the APS linac test stand are discussed

Additional details

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
281
Journal Issue
1
Journal Page Range
p. 248-255.
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
4. annual accelerator instrumentation workshop.
Dates
27-30 Oct 1992.
Place
Berkeley, CA (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
25040173
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ADVANCED PHOTON SOURCE; BEAM MONITORING; BEAM POSITION; DESIGN; ELECTRON BEAMS; ELECTRONIC CIRCUITS; LINEAR ACCELERATORS
Descriptors DEC
ACCELERATORS; BEAMS; LEPTON BEAMS; MONITORING; PARTICLE BEAMS; RADIATION SOURCES; STORAGE RINGS; SYNCHROTRON RADIATION SOURCES

Optional Information

Secondary number(s)
CONF-9210246--.