Control system of power supply for HT-7 diagnostic neutral beam source was composed of PLC, timer and master control logic. The experimental results show the good facility and reliability. The arcing and beam extraction are studied experimentally. The influences on the beam current are observed by adjusting arc voltage and gas injection at different cases. The neutral beam power of 50 kW and beam current about 3.6A were obtained in this operation period with 35 kV HV and 80A arc current. (authors)