Published September 1999 | Version v1
Journal article

Percutaneous CT-guided lung biopsy: sequential versus spiral scanning. A randomized prospective study

  • 1. Department of Medical Imaging, University Hospital Sart Tilman, Liege (Belgium)
  • 2. Department of Medical Statistics, University Hospital Sart Tilman, Liege (Belgium)

Description

The aim of this study was to evaluate in a prospective and randomized study spiral versus sequential scanning in the guidance of percutaneous lung biopsy. Fifty thoracic lesions occurring in 48 patients were biopsied by a senior and a junior operator. Six different time segments of the procedure were measured. Scanning mode versus length of procedure, pathological results, irradiation and complications were evaluated. Total duration of the procedure and of the first sampling was significantly longer with spiral CT for the senior operator (p < 0.004). No significant time difference was observed for the junior operator. Diameter of the lesion, depth of location, position of the patient and needle entry site did not influence the results. The sensitivity was 90.9, specificity 100, positive predictive value 100 and negative predictive value 60 % for spiral CT, and 94.7, 100, 100 and 85.7 % for sequential CT, respectively. Eleven pneumothoraces and ten perinodular hemorrhages were seen with spiral CT and six and ten, respectively, with sequential CT. The mean dose of irradiation was 4027 mAs for spiral CT and 2358 mAs for conventional CT. Spiral CT does neither reduce procedure time nor the rate of complications. Pathological results do not differ compared with sequential CT, and total dose of irradiation is higher with spiral scanning. (orig.)

Additional details

Publishing Information

Journal Title
European Radiology
Journal Volume
9
Journal Issue
7
Journal Page Range
p. 1317-1320
ISSN
0938-7994
CODEN
EURAE3

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
30043731
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOPSY; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; LUNGS; RADIATION DOSES; SENSITIVITY; SPECIFICITY; SPIRAL CONFIGURATION
Descriptors DEC
BODY; CONFIGURATION; DIAGNOSTIC TECHNIQUES; EVALUATION; ORGANS; RESPIRATORY SYSTEM; TOMOGRAPHY

Optional Information

Notes
With 4 tabs., 5 refs.