Published April 2010 | Version v1
Journal article

Free flow electrophoresis separation and AMS quantitation of 14C-naphthalene-protein adducts

  • 1. Center for AMS, LLNL, 7000 East Avenue, Livermore, CA 94551 (United States)
  • 2. Department of Molecular Biosciences, School of Veterinary Medicine, UC Davis, Davis, CA 95616 (United States)

Description

Naphthalene is a volatile aromatic hydrocarbon to which humans are exposed from a variety of sources including mobile air sources and cigarette smoke. Naphthalene produces dose-(concentration)dependent injury to airway epithelial cells of murine lung which is observed at concentrations well below the current occupational exposure standard. Toxicity is dependent upon the cytochrome P450 mediated metabolic activation of the parent substrate to unstable metabolites which become bound covalently to tissue proteins. Nearly 70 proteins have been identified as forming adducts with reactive naphthalene metabolites using in vitro systems but very little work has been conducted in vivo because reasonably large amounts (100 μCi) of 14C labeled parent compound must be administered to generate detectable adduct levels on storage phosphor screens following separation of labeled proteins by 2D gel electrophoresis. The work described here was done to provide proof of concept that protein separation by free flow electrophoresis followed by AMS detection of protein fractions containing protein bound reactive metabolites would provide adducted protein profiles in animals dosed with trace quantities of labeled naphthalene. Mice were administered 200 mg/kg naphthalene intraperitoneally at a calculated specific activity of 2 DPM/nmol (1 pCi/nmol) and respiratory epithelial tissue was obtained by lysis lavage 4 h post injection. Free flow electrophoresis (FFE) separates proteins in the liquid phase over a large pH range (2.5-11.5) using low molecular weight acids and bases to modify the pH. The apparatus separates fractions into standard 96-well plates that can be used in other protein analysis techniques. The buffers of the fractions have very high carbon content, however, and need to be dialyzed to yield buffers compatible with 14C-AMS. We describe the processing techniques required to couple FFE to AMS for quantitation of protein adducts.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nimb.2009.10.164

Additional details

Identifiers

DOI
10.1016/j.nimb.2009.10.164;
PII
S0168-583X(09)01213-0;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section B, Beam Interactions with Materials and Atoms
Journal Volume
268
Journal Issue
7-8
Journal Page Range
p. 1324-1327
ISSN
0168-583X
CODEN
NIMBEU

Conference

Title
11. international conference on accelerator mass spectrometry
Dates
14-19 Sep 2008
Place
Rome (Italy)

Optional Information

Copyright
Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.