Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy
- 1. Imaging Research, Sunnybrook and Women's College Health Science Centre, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada)
- 2. ANRAD Corporation, 4950 Levy Street, Saint-Laurent, Quebec H4R 2P1 (Canada)
Description
The imaging performance of an amorphous selenium (a-Se) flat-panel detector for digital fluoroscopy was experimentally evaluated using the spatial frequency dependent modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). These parameters were investigated at beam qualities and exposures within the range typical of gastrointestinal fluoroscopic imaging (∼0.1-10 μR, 75 kV). The investigation does not take into consideration the detector cover, which in clinical use will lower the DQE measured here by its percent attenuation. The MTF was found to be less than the expected aperture response and the NPS was not white which together indicate presampling blurring. The cause of this blurring was attributed to charge trapping at the interface between two different layers of the a-Se. The effect on the DQE was also consistent with presampling blur, which reduces the aliasing in the NPS and thereby reduces the spatial frequency dependence of the DQE. (The DQE was independent of spatial frequency from 0.12 to 0.73 mm-1 due to antialiasing of the NPS.) Moreover, the first zero of the measured MTF and the aperture response appeared at the same spatial frequency (6.66 mm-1 for a pixel of 150 μm). Hence, the geometric fill factor (77%) was increased to an effective fill factor of 99±1%. A large scale (∼32 pixels) correlation in the noise due to the configuration of the readout electronics caused increased noise power in the gate line NPS at low spatial frequency (<0.1 mm-1). The DQE (f=0) was exposure independent over a large range of exposures but became exposure dependent at low exposures due to the electronic noise
Additional details
Identifiers
- DOI
- 10.1118/1.1707755;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 31
- Journal Issue
- 5
- Journal Page Range
- p. 1166-1175
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 36002682
- Subject category
- S60: APPLIED LIFE SCIENCES; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- APERTURES; ATTENUATION; BEAMS; FILL FACTORS; FLUOROSCOPY; IMAGES; MODULATION; NOISE; QUANTUM EFFICIENCY; RADIATION DETECTORS; SELENIUM; SPECTRA; TRANSFER FUNCTIONS; TRAPPING; X-RAY DETECTION
- Descriptors DEC
- BIOMEDICAL RADIOGRAPHY; DETECTION; DIAGNOSTIC TECHNIQUES; EFFICIENCY; ELEMENTS; FUNCTIONS; MEASURING INSTRUMENTS; MEDICINE; NUCLEAR MEDICINE; OPENINGS; RADIATION DETECTION; RADIOLOGY; SEMIMETALS
Optional Information
- Notes